Sign In | Join Free | My fazendomedia.com
China Hebei Kaixiang Electrical Technology Co., Ltd logo
Hebei Kaixiang Electrical Technology Co., Ltd
Active Member

6 Years

Home > Dummy Load Bank >

1500 KVA Apparent Power Dummy Load Bank 4 Wire With Smoke Fog Protection

Hebei Kaixiang Electrical Technology Co., Ltd

1500 KVA Apparent Power Dummy Load Bank 4 Wire With Smoke Fog Protection

  • 1
  • 2

Brand Name : Kaixiang

Model Number : AC430V-1500kvA

Certification : ISO9001

Place of Origin : China

MOQ : 1 set

Price : negotiable

Payment Terms : Western Union, L/C, T/T

Supply Ability : 30Sets/Month

Delivery Time : Within 50 working days

Packaging Details : Packaged in container

Model : AC430V-1500kvA

Rated power : 1500 kvA

Voltage : AC 430 V

PF(Power Factor) : 0.8

Display Precision : 0.5 class

Dimension : 4000mm×2350mm×2591mm(L×W×H)

Contact Now

AC430V-1500kvA Dummy Load Bank In Resistive Inductive And High Performance

Introduction

Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket base, castors. Larger load banks, typically above 1500kVA, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.

Tailor-made load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.

Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application. They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.

Application

AC430V-1500kvA Dummy Load Bank can be used in a wide variety of applications, such as

1. Ups system testing

2. Battery system testing

3. Load optimization in prime power applications

4. Factory testing of turbines

5. factory testing of engine generator sets

6. To reduce wet stacking problems

7. Periodic excercising of stand-by engine generator sets

Technical specification

System Parameter
Rating voltage/frequency 430V, 3 phase 4 wire 50Hz
Max Load Power

Apparent Power: 1500KVA

Resistive Load: 1200kW

Inductive Load: 900KVAR

Load Resolution

Resistive Load: 14 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW, 200kW

Inductive Load: 13 steps

1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 100KVAR,200KVAR,200KVAR,200KVAR

Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 wire, 415V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 4000mm×2350mm×2591mm(L×W×H)
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor Kaixiang
Data Processing Software Kaixiang
Main features

(1) Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

(2) Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

(3) Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

(4) Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

(5) Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

(6) Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

(7) Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

(8) Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.

(9) Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

1500 KVA Apparent Power Dummy Load Bank 4 Wire With Smoke Fog Protection


Product Tags:

water cooled load bank

      

capacitive load bank

      
Best 1500 KVA Apparent Power Dummy Load Bank 4 Wire With Smoke Fog Protection wholesale

1500 KVA Apparent Power Dummy Load Bank 4 Wire With Smoke Fog Protection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hebei Kaixiang Electrical Technology Co., Ltd
*Subject:
*Message: